FACILITIES
Hyperbaric Pressure Chamber
The pressure chamber at soaked technologies is rated to 1200MSW. Each test comes with an automatically generated test report.
We have 3 penetrators available, 2x ½ inch BSP and 1x 7/16th UNF. As a standard we have one 7 pin bulkhead installed, we can populate penetrators electrically and hydraulically per client request.
Key Features
- 1200 meter depth rated
- Pressure data logger
- Automatically generated test-report
- 7/16 UNF and ½” BSP penetrators available for electronic/hydraulic connections
Specifications
Internal diameter |
455mm |
Internal length |
1200mm |
Pressure rating |
120bar |
Pressure media |
Liquids |
Pressure sensor resolution |
0.2 bar |
Pressure sensor accuracy |
+-0.5% |
SM4/SM7 TESTER
The Soaked Technologies SM4-7 tester is a next generation service tool for Seaeye SM4 and SM7 thrusters. It is capable of supplying the thruster with 36V DC as a safe working voltage for “on bench” diagnostics and trouble shooting.
Additionally the unit can run fully auto mated test cycles monitoring voltages, current and line isolation as well as measuring bollard thrust. It can also be used for endurance tests to prove thruster modifications.
Key Features
- Large 5 cubic meter fresh water test tank
- 100KG bollard thrust measurement
- 550MΩ line isolation measurement
- 2.8KW forced-air cooled meanwell power supplies
- Automated test cycle
- DC safe working voltage supply
- Yearly calibration of A/D converters
- Fully automatic comprehensive reporting
Specifications
PWM speed signal |
12V, 250mA, 490Hz, 0-100% |
Directional signal |
+-24VDC +-2% 250mA |
DC safe working voltage supply |
36VDC +- 1% |
SM4 power voltage supply |
250VDC +-2% |
SM7 power voltage supply |
500 VDC +-2% |
DC current supply |
5.6A |
Voltage and current measurement accuracy |
+-1% |
Earth resistance measurement |
2KΩ to 0.1Ω +-2% |
Directional line isolation measurement |
200KΩ to 200MΩ +-5% |
SM4 DC line isolation measurement |
500KΩ to 250MΩ +- 5% |
SM7 DC line isolation measurement |
700KΩ to 550MΩ +-5% |
Bollard thrust measurement |
0-100 KGf +-5% |